___________________________________________________ ___________________________________________________ ________________________ 1 of 3 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com ac input 80-270vac, 47-63 hz single phase. (see note 1) turn on time 500msec maximum input current input 120vac: 4.2a, 230vac: 2.1a hold - up time 20 ms at 400w inrush current input active circuit, 37a max overvoltage protection see chart input fuse s f1, f2: 6.3a overload protection cycling type, 470w typical power factor 0.99 typical, 0.96 minimum overtemperature protection provided on all models, auto- recover y. see page 2 for cooling information efficie ncy typical 88% @ 120vac, 91% @ 240vac remote sense compensates for up to 500mv drop on output leads switching frequency output: 170khz 8khz; pfc: 9 0khz, 8khz; bias: 100khz, 6 khz output power 400w with fan cooling. see derating chart for othe r conditions. peak: 450w for 1 min., 10% duty cycle safety standards medical: en/iec/ul 60601-1, csa 601.1 ite: csa/en/iec/ul 60950-1, 2nd edition ripple and noise 1% pk-pk max., 20mhz bw, differential mode isolation input-output: 4000vac, in put-ground: 1500vac, output-ground output voltage s see chart. voltages adjustable +/- 5% earth leakage current 100 a at 120vac, 60hz normal. 400 a at 264vac, 60hz sfc. total regulation see chart operating temperature 0 to 70 c, refer to derating curve for ratings >40 c minimum load not required storage temperature -40 to +85 c transient response 500 s to 1%, 0.2a/ s, 3.5% deviation relative humidity 5% to 95%, non-condensing shock and vibration shock: mil-std-810e, 516.4 part iv vibration: 5hz ? 500hz, 2.5 grms altitude operating: -500 to 10,000 ft. non-operating: -500 to 40,000 ft. mint1400a 400w single output series medical ? universal input power supply 2 year warranty ? compact 3.94? x 7? x 1.58?, 1u compatible ? 9.5 w/in3 ? 300w convection rating ? efficiency up to 91% ? 12vdc to 48vdc outputs, up to 400w ? remote on/off by ps-on signal ? safety approved to medical and ite standards ? en/iec/ul60601-1 and csa 601.1 ? csa/en/iec/ul60950-1, 2 nd edition ? compliant to en55011/22 conducted noise, class b ? rohs compliant ? category 6 specifications all specifications are typical at nominal input, fu ll load at 25 c unless otherwise stated . model number key 12 output voltage: "12" = 12v output, "24" = 24v outpu t, etc. 10 "10" = output connections - bus bars w ith #10 screw s mint "l" = input connector - eby p/n 5002-03-n-12 01 01 = standard model, 02 and higher indicates a m od ified m odel. product fam ily: "m" = medical, "i" = internal, "nt" = new technology 1 # of outputs 400 output pow er (watts) - "400" = 400w a model configuration: "a" = original configuration l
___________________________________________________ ___________________________________________________ ________________________ 2 of 3 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com mint1400 output power derating chart 0 50 100 150 200 250 300 350 400 450 0 10 20 30 40 50 60 70 ambient temperature (deg c) output power (watts) external 200 lfm fan convection mint1400a1210l01 12v 33.0a 25.0a 1% 2% MINT1400A2410L01 24v 16.7a 12.5a 1% 2% mint1400a2810l01 28v 14.3a 10.7a 1% 2% mint1400a4810l01 48v 8.30a 6.30a 1% 2% note 1: when the input voltage is <90vac, derate o utput power to 300w fan cooled, or 250w convection. inhibit : ttl low to inhibit dc ok: high when output is >90% of nominal ps off: ttl high to inhibit fan output: 12vdc @ 250 ma. pwr ok ttl high when ac is ok, 100-200 ms delay. 5v standby voltage: always on, up to 100ma. pwr ok pf low 4 ms warning before loss of output regulatio n. conducted emissions en55011/22 class b ra diated emissions en55011/22 class a voltage fluctuations en61000-3-3, complies static discharge immunity en61000-4-2, 6kv contact discharge, 8kv air dischar ge radiated rf immunity en61000-4-3, 3v/m. eft/burst immunity en61000-4-4, 2kv/5khz.. line surg e immunity en61000-4-5, 1kv differential, 2kv common-mode conducted rf immunity en61000-4-6, 3vrms power frequency magnetic field immunity en61000-4-8, 3a/m voltage dip immunity en61000-4-11 criteria a @ 250 watts or less. line frequency harmonics en61000-3-2, class a mint1400a 400w single output series medical ? universal input power supply 2 year warranty output parameters model output output current ripple total number volts (v) fan cooled convec tion & noise regulation emi/emc compliance signals out put power derating curve note: for convection cooling, the power supply is required to be mounted on a heatsink or system chassis with a minimum of 150 in2 of surface area.
___________________________________________________ ___________________________________________________ ________________________ 3 of 3 sl power electronics corp 6050 king drive ventura, ca 93003 phone 805.486.4565 fax 858.712.2040 email: info@slpower.com www.slpower.com input connector (tb1): signal connector (j3) (optional) : pin 1 pin 2 pin 3 manufacturer's p/n: pin 1 pin 2 pin 3 pi n 4 manufacturer's p/n: ac line neutral ground eby p/n 5002-03-n-12 ps off inhib it pwr ok dc ok amp p/n 640456-8 pin 5 pin 6 pin 7 pin 8 rtn +5v standby ?????-? ? ?????????+? 3 12 2013
|